DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1186UDS1-BD (UDS1 Interface Circuit Pack)
3
Control Channel Looparound Test (#52)
This test queries the circuit p ack for its circuit p ack code and vintage and verifies
its records.
Table 3-515. TEST #50 NPE Connection Audit Test
Error
Code
Test
Result Description/ Recommendation
None
2100 ABORT System resources required for t his test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1019 ABORT The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The circuit pac k’s SCOTCH-NPE chip have been updated with its translation.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page