DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1272VC-LEV (Voice Conditioner DSP Port Level)
3
Error Log Entries and Test to Clear Values
Notes:
a. The number of VC resources in the system that are in service has fallen
below the calculated minimum value. If the number of in-servic e VC ports
falls below the MMCH port ca pacity (value entered in the Minimum
Maintenance Threshold VCs field on the system p arameters maintenance
form), a VEC-LEV error is logged. If this outage c ontinues for 15 minutes a
MAJOR alarm is raised. To resolve this alarm, correct the out-of-servic e
problem by following the procedures below:
1. See ‘‘VC-DSPPT’’ and ‘‘VC-BD’’ and resolve any ass ociated alarms.
2. If a VC-LEV error/alarm exist and none has been raised again st
VC-BD or VC-DSPPT maintenance objects, a VC circuit pack may
have been removed from service c ausing the VC-LEV error/alarm.
To resolve a VC-LEV MAJOR alarm, restore the number of VC ports
available for service to b e equal to or more than the calculate d port
capacity. See ‘‘Reso lving VC-LEV Err ors/Al arms’ above for details.
System Technician-Demanded Tests:
Descriptions and Error Code
There are no System Technician-Demanded test for VC-LEV.
Table 3-543. VC-LEV Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/ Off
Board Test to Clear Value
1 (a) Any None MAJOR OFF