DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-120ATM Tips
1
Figure 1-49. A500: show signaling summary screen
Ensure that the fields have the values indicated below.
4. Enter show system interfaces on the A500 console. Figure 1-50 shows
an example of the screen output.
SAP State Up
If it is PHY_DOWN or DOWN, then there is probably a loss of signal
on the port in question. This command detects a continuity
problem only with the Receive (right-hand) fiber; it does not
detect the state of the Transmit (left-hand) fiber.
State The value of may be UP or DOWN, depending on the
administration of the port. It may be necessary to
re-administer the A500 port b oards. Refer to the
Cajun A500 Quick Reference
for further information.
A500:show signaling summary
Port loc VCI SAP IntType Signaling ILMI SAP State State
------ ------- --- ------- ----------- ---- ------------ -----
A1.1 1 1 Network UNI3.1 No UP UP
A1.2 2 2 Network UNI3.1 No UP UP