DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-543DIOD-TRK (DIOD Trunk)
3
Port Audit Update Test (#36)
This test sends updates of the CO port trans lation for all ports on the circuit p ack
which have been translated. The update is non-disrup tive and guards ag ainst
possible corrup tion of translation data contained on the circuit pac k. No
response message is expec ted from the circuit p ack once it rece ives translation
updates. The port translation d ata includes: g round or loop start trunk, tone or
rotary dialing trunk, rotary d ialing inter-digit timing , network balance R/RC, and
disconnect timing .
7 FAIL 1. Check for errors on TONE-BD or TONE-PT. If there are errors, take the
appropriate actions.
2. If the Reflective Loop Around Test fails for all ports on a circuit pack, a
-5 volt power problem is indicated.
3. Rerun the test.
4. If the test fails again, replace the circuit pac k.
PASS CO Trunk Loop Around and Conference Test is successful. User-reported
troubles on this port should be investigated by using other port tests and
by examining trunk or external wiring.
Table 3-230. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page