Maintenance Commands

2-152list testcalls

2
The measurements are produced b y a set of analog trunk tests. The tests are initiated by a maintenance d emand test or by a set of sc heduled tests. The largest portion of these measurements are g enerated through sched uled testing during system quiet hours (hour s where the traffic volume is low). Each trunk test performed by the s ystem stores the results in a database. The trunk measurements in this database reflect the state of eac h trunk at the time of its last test.
Action/Object Qualifiers/Options Qualifier/Option Description
list testcalls

detail

summary

Detailed measurement report displayed
Summary measurement report displayed
grp group number Measurements for a specific trunk group d isplayed. When used
with the

to-grp

option, this option is the starting trunk group in a
range of user-specified trunk group s.
to-grp group number Measurements for all trunk groups from 1 to the specified
“to-grp” trunk group are displayed. When used with the

grp

option, this option is the ending trunk group in a rang e of
user-specified trunk group s.
mem member number Measurements for a specific trunk group memb er displayed.
When used with the

to-mem

option, this option is the starting
trunk group member in a range of us er-specified trunk group
members.
to-mem member number Measurements for all trunk group members from 1 to the
specified “to-mem” trunk g roup member displayed. When used
with the

mem

option, this option is the ending trunk g roup
member in a range of user-specif ied trunk group members.
port location Measurements for a specific trunk circuit (p ort) displayed
result result identifier This option is used to filter out all measurement results that do
not match the user-specified result, that is, only measurement
results that match the user specified result are disp layed.
Examples of results are pass, marg, fail, etc.
not-result result identifier This option is used to filter out all measurement results that do
match the user-specified result, that is, only measurement
results that do not match the user specified result are displayed.
Examples of results are pass, marg, fail, etc.
count count number This option is used to sp ecify (limit) the number of records
displayed.
print Report sent to printer
schedule Command is validated and then a sched uling form displays to
schedule execution of the command . The command is then
placed in the command q ueue and is executed at the specified
time. The information displayed by the command is sent to the
system printer instead of the screen.1
1 Refer to the Report Scheduler and System Printer feature specification for more details.