DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-85LED Interpretation
1
‘‘Control and Port Circuit Pack Status LEDs’
‘‘Power Supply LEDs’’
Terminal Alarm Notification
Terminal Alarm Notification is an optional feature which displays several types of
alarms on voice terminals with adm inistered feature buttons or the attendant
console. A maximum of ten dig ital and/or hybrid voic e terminals may be used .
When an alarm occurs, the green status LED assoc iated with the assigned
button will be in a steady st ate. The lamp may be turned off by pressing the
button associated with the li ghted alarm lamp. If the l amp is turned off, and the
alarm has not been resolved b y the time maintenance resched ules testing, the
green status LED will resume its steady state. The following alar ms are
displayed:
ac-alarm Administered Connection Alarm: a locally administered
connection (ADM-CONN) has a Major, Minor , or Warning
alarm active.
pr-awu-alm Auto Wakeup Journal Printer Alarm: the automatic wakeup
journal printer has a Major, Minor, or Warning a larm active.
off-bd-alarm DS1 or ATM Facility Alarm: an off-board Major, Minor, or
Warning alarm is active on a DS1-BD, UDS1-BD, or
ATM-TRK board.
trk-ac-alm Facility Access Alarm: The facility ac cess trunk test feature
is activated.
major-alrm Major Alarm: The system has logged a Major Al arm.
mj/mn-alrm Major/Minor Alarm: The system has logg ed a Major or Minor
Alarm.
pr-p ms-a lm PMS Printer : The Pr oper ty Man agem ent Sy stem p rint er has
a Major, Minor, or Warning alarm active.
rs-alert Reset-Alert: reset system 2 or 3 has been performed.
cdr1-alrm Call Detail Recording Alarm: The Primary CDR Link has a
Major, Minor, or Warning alarm active.
cdr2-alrm Call Detail Recording Alarm: The Secondary Link has a
Major, Minor, or Warning alarm active.
pr-sys-alm S ystem P rinter Alarm: The System Printer (SYS-PR NT) has a
Major, Minor, or Warning alarm active.
pms-alarm The Property Management System has a Major, Minor or
Warning alarm active.