DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-682H323-STN (H.323 IP Station)
3
Media Path PING Test (#1374)
This test is nondestructive.
The test selects a Media Processor board. It then requests the local Media
Processor to execute a PING on the endpoint ad dress. If the PING is successful,
the test passes, if the PING is not successful, the te st fails.
Services can execute the stand ard ping command using the Media Processor
board address and endpoint IP add ress to see the actual round-trip delay.
This test checks the IP network connectivit y needed for audio p ackets to be sent
to the endpoint.
This nondestructive test runs due to in- line errors, during period ic and sched ule
maintenance, and on demand .
Table 3-287. TEST #1374 Media Path PING Test
Error
Code
Test
Result Description/ Recommendation
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2806 ABORT No Media Processor board found to use for this test.
ANY FAIL The system could not PING the registered end point from a Media Proc essor
board. This may result in calls with no talk path.
1. If the Registration Status Inquiry Test (#1372) fails, follow those
procedures.
2. Refer to MEDPRO, Test #1378, for a detailed description of the error
codes.
PASS PING thr ough this Me dia Pr ocess or is s ucc essful .