DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-877PE-BCHL (PRI Endpoint Port)
3
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM Bus errors. The status health command can be used to determine
if the system is experiencing heavy traffic. Refer to TDM Bus Maintenance
to diagnose any ac tive TDM Bus errors.
1. If system has no TDM Bus errors, and if it is not handling heavy traffic,
repeat the test at 1-minute interva ls a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service. The list measurements tone-receiver
command displays information on the system’s tone receiver.
1. Look for TTR-LEV errors in the Error Log. If errors are present, refer to
TTR-LEV.
2. Look for TONE-PT errors in the E rr o r Log. If errors are present, refer to
TONE-PT.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use status
pri-endpoint <extension> commands to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1117 ABORT A service state audit message is outstanding.
1. Wait 2 minutes and then try again.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2020 ABORT The test did not run due either to an already existing error on the specific
port or to a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-378. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page