DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1293XXX-BD (Common Port Circuit Pack)
3
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension. Use the status station command to determine th e service state
of the port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1008 ABORT Could not allocate a ringing circuit for one of the following reasons: all the
ringing circuits are in use; the ringing generator is defec tive; ringing
generator is not wired correctly.
1. If the test continues to abort, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to RING-GEN Maintenance
documentation and try to resolve any problem(s). Go to Step 2.
b. If there are no RING-GEN errors, and the test continues to abort,
issue the test board PCSS command on other TN742, TN769, or
TN746 Analog circuit packs. If an ABORT with error code 1008
occurs for this test on other circuit packs as well, the ringing
generator may be defective or may not be wired properly. Refer to
RING-GEN Maintenance documentation for details. If an ABORT
with error code 1008 does NOT occur on the other ports, then all
four ring generators are in use. Exit from this documentation.
2. Retry the command.
FAIL No ringing current is detec ted. The ringing application circ uitry on this
circuit pack prob ably is not healthy.
1. Retry the command again.
2. If the test continues to fail, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to the RING-GEN Maintenance
documentation and try to resolve any problem(s).
b. If there are no RING-GEN errors, replace the circuit pack.
3. Retry the command again.
PASS Ringing current is detected or this vintage of the Analog Line circ uit pack
does not support the Ringing Application Circ uit Test. Analog Line circuit
packs that DO NOT support Test #51 include TN742 Vintage 3 and earlier.
Table 3-553. TEST #51 Ringing Application Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page