DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-874PE-BCHL (PRI Endpoint Port)
3
b. This is a software audit error that does not indic ate any hardware
malfunction. Run the Short Test Sequence and investigate the associa ted
errors (if any).
c. The PRI Endpoint Port has been busied out by a busyout pri-endpoint
<extension> command or b y a busyout port <PCSSpp> command. No
wideband c alls can be made to this p ort (although wideba nd calls can still
be made to other ports wi thin this PRI Endpoint if others ports are in
service).
d. The far-end terminal adapter c hanged its ISDN
service
state to either
"out-of-service" or "maintenance." This may be a temporary condition d ue
to the testing of this port by the far-end terminal adapter
or
by a hardware
problem with the port. Outg oing calls to the terminal ad apter are not
allowed over the port (althoug h calls can still be ma de to other ports that
are in service within the same PRI Endpoint). To investigate the status of
the port, issue the status pri-endpoint <extension> command.
e. This error type indicates that the circ uit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
f. This error type indicates a disagreement b etween this switch and the
terminal adapter at the other end of the connection with regard to the
ISDN service state of the PRI Endpoint Port. This switch tries to recover by
performing a servic e state audit. The status pri-endpoint <extension>
command can be used to determine the state of the port.
When running the Short Test Sequence, pay close attention to the results
of the Service State Audit Test (#256).
g. This port is not recognized b y the far-end terminal adap ter. Investigate the
PRI Endpoint administration for both the switc h and the terminal adapter
and make changes as nec essary.
h. The Conference Circuit Test (#7) failed on this port. See Test #7 for the
repair procedures.
i. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for the repair
procedures.
j. This error indicates a failure of the UDS1 Interface circuit p ack. When
running the Short Test Sequence, the results of the Signaling Link State
Check Test (#255) are important.
k. Two Service State Audit attempts have failed (see Test #256). The port is
not usable for any outgoing calls to the terminal adap ter (although
incoming calls from the termi nal adapter are accep ted over this port, other
ports in the PRI Endpoint can still b e used for both incoming and outgoing
calls to and from the terminal ad apter) until the test passes and the port
state is changed to in-ser vice (use the status pri-endpoint <extension>
command to investigate th e port status).