DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-159ATM-EI (Expansion Interface Circuit Pack)
3
Error Type 3585:
Aux Data (Error Type 3585 only):
1. If the board is in a PPN, or if the system has duplic ated PNC:
a. Test the ATM-EI (test board UUCSS l).
b. If Error 3585 is detected ag ain, or if the board is not
recognized anymore, replac e the ATM-EI circuit pack.
2. If the system does
not
have duplicated PNC, and the circuit pack is
in an EPN:
a. Replace the ATM-EI circuit pack.
Error Type 3586: Framer Looparound Test #1260 failed.
Aux Data (Error Code 3586 only):
1. If Error Type 3586 is detected again, replac e the circuit pack.
Aux
Data Description
1 ATM framer failure
2 NCE failed (only from ATM-EIs in EPN)
4 TDM_PLD _FAILED
5 DSP_AL L FAILED
6 Receive Network Processor (RNP) failure
7 Transmit Network Processor (TNP) failure
8 MEMORY read/write failure
Continued on next page
Aux
Data Description
2 Packet path failed
3 Circuit path failed
4 TDM loop cannot be created
5 Packet loop cannot be created
Continued on next page