DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1018SYS-PRNT (System Printer)
3
3. 4- time-out during setup attem pt. Most likely due to prob lem with
physical link or printer st atus.
4. internal system error. Most likely temporar y/sporadic failure.
5. the data module the pri nter is trying to use is busy with ano ther call.
Use the Status data module command to determine when th e port
is available for testing.
Refer to the ‘‘Procedures for Restoring the System Printer Link’’ section for
recommended maintenanc e strategy.
c. The SYS-PRNT was inte rrup ted b ec ause o f one o f the follo wing reaso ns:
1. the cable to the SYS-PRNT output device is disconnec ted;
2. the SYS-PRNT output device is p owered off;
3. the data exten sion t o whi ch th e SYS-PRNT ou tput dev ice c onne cts
has been busied out;
4. internal software error.
Check the connectivity of the wires and cables among the wall jacket,
data modu le, an d SYS-PRNT outp ut de vice . Follo w the instr ucti ons
provided in the ‘‘Procedures for Restoring the System Printer Link’’ section.
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to add ress,
always investigate errors in the order they are p resented in the table below. By
clearing error cod es associated with the
Link Retry Test
, for example, you may
also clear errors generated from oth er tests in the testing sequenc e.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND
Link Tear Down Test (#213) X X ND