DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-950PR-MAINT (Maintenance Processor)

3
NOTE:
A dial-up (through the INADS po rt) does not display the results discussed in the previous paragrap h. However, a dial-up throug h data channels does display these results.
Table 3-410. TEST #104 MTP Dual Port Ram Test
Error
Code
Test
Result Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT (Refer t o STBY-SPE Mai ntena nce d ocum entat ion for a des crip tion o f these
error codes.)
1000 ABORT System software resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1030 AB ORT The comp onent on whi ch the test w as to b e run is on the Standb y SPE. This
test may be run on this component only when it resides on the Active SPE.
1. For a recommended maintenance procedure, refer to ABORT Error
Code 1030 in STBY-SPE Maintenance documentation.
2000 ABORT Response to the test request was not received within the allowable time
period.
2028 ABORT System software resources required for this test are not available.
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The dual port RAM is not functioning correctly. Communication between
the processor and MTP is lost. The system is not able to report
environmental alarms, communicate with the Standby SPE, or reboot from
tape, if necessary.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
PASS Dual port RAM is functioning. Communication exists between the
80286/386 Processor circuit pack and the MTP.
Continued on next page