DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-1288XXX-BD (Common Port Circuit Pack)

3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. This error indicates the circuit p ack totally stopped func tioning or it was physically removed from the system. This error type is not applicable to ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
NOTE:
The alarm is logged ap proximately 11 minutes after the circuit pac k has been removed and/or SAKI Sanity Test (#53) fails.
Common Port Circuit Pack Maintenance Error Log Entries
Error Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test board PCSS sh r 1
1(a) 0 Circuit pack
removed or SAKI
Sanity Test (#53)
MINOR ON
18(b) 0 busyout board PCSS WARNING OFF release board PCSS
23(c) 0 None WARNING OFF
125 (d) None MINOR ON
257 65535 Control Channel Test
(#52) MINOR ON test board PCSS sh r 20
257 (e) Any N o ne
267 (d) 0 None WARNING ON
513 (f) Any None MINOR ON test b oard PCSS sh
769 (g) 4358 None
1025 (h) 4363 NPE Audit Test (#50) test board PCSS l r 20
1281 (i) Ringing Application
Test (# 51) MINOR ON test board PCSS r 2
1538 (j) Any None WARNING/
MINOR ON
1793 (k) Neon Test (#220) MINOR ON test board PCSS r 2
3840 (l) Any None
3999 (m) Any None