DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-631E-DIG-STA (Emulated Digital Line)
3
Notes:
a. Maintenance personnel has b usied out the port in q uestion. Make sure
that the port is released from b usyout by using the release port PCSSpp
command.
b. The circuit pack has been removed or has been in sane for more than 21
minutes. To clear the error, reinsert or replace the circuit p ack.
c. The local loop test failed . Each failure increments the counter b y 1 when
the local loop test fails. The counter is decremented when the loop test
passes. When the counter reaches a threshold of 3, an on-board MINOR
alarm is raised. This is the code that is g enerated when the link between
the circuit pack an d the voice terminal is suc cessfully reset. No technician
action is necessary.
d. The NPE Cross talk test failed. The counter is incremented b y 1 when the
NPE Cross talk test fails. The counter is decremented by 1 when t he NPE
Cross talk test passes. When the counter reaches a threshold of 3, an
on-board MINOR alarm is raised and the board is taken out of servic e.
e. The station went off-hook while it was in the ready-for-service state. Use
the status station command to d etermine the state of the station. The
off-hook should have moved the station to read y-for-service. No technic ian
action is necessary.
f. No terminal is connected to the Digital Line board. No maintenanc e action
is required.
3840 (f) 40965 None
3841 (g) 41029 None
2304 (h) None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test S equence. Refer to the appropriate
test description and follow the recommended proc edures.
2. Major alarms may be downg raded to Warning al arms based on the value used in the set options
command.
Table 3-259. Digital Line Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page