DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-909PKT-INT (Packet Interface)
3
Table 3-390. TEST #886 Maintenance Looparound Test
Error
Code
Test
Result Description/ Recommendation
1006
1137 ABORT Packet Interface is in the out-of-service state so normal maintenance tests
will not run on it.
1. Use the
display system-parameters maintenance
command to identify
which C-LAN circuit pack is administered with the Bus Bridge. Verify that
the C-LAN circuit pack is present and is not alarmed.
2. Reset the Packet Interface using the reset packet-interface AS
command. Refer to the Packet Interface Reset Test (#889)
maintenance documentatio n for further action.
1139 ABORT The Packet Bus is alarmed
1. Try to retire the alarm associated with the Packet Bus. Refer to the Alarm
Log through the display al arms command. Refer to the maintenance
documentation for Packet Bus Maintenance for further action.
2. Retry the command when the alarm associated with the Packet Bus is
retired.
1373 ABORT Could not establish the link loop around link to run this test.
1. Retry the command at 1-minute intervals, a maximum of 3 tim es.
2060 ABORT Packet bus link went down during maintenance looparound test.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
2. If there are errors associated with the Packet Bus, refer to the
maintenance information assoc iated with the Packet Bus.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, a maximum of 5 tim es.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, a maximum of 5 tim es.
NO
BOARD The Packet Interface is not detected as being physically present.
1. Reboot the system, then retry the command. If the NO BOARD
indication persists, replace the TN798 Processor circuit pack.
Continued on next page