DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-46display alarms
2
Field descriptions
Port Lists the location codes for the alarmed object, as follows:
Circuit packs locations display as:
cabinet-carrier-[ slot]-[circ uit]. Example: 01C0702.
Port network locations display as: p ort network number-bus.
Example: PN 02B. PN 02 = Port Network (PN) number and A
or B = bus.
Fiber link locations disp lay as: fiber link number-PNC side.
Example: x A-PNC. “X” = fiber link number and “A” = PNC
side [A or B].
Maintenance
Name Lists the logical name of the maintenanc e object with the alarm.
On Brd A y (yes) indicates the fault was found on the associated c ircuit
pack. A n (no) indicates the fault is not connected to the circ uit
pack.
Alt Name Identifies the location of maintenanc e object, as follows:
Station = extension number
Trunk = Group number (78/__) or group and memb er
numbers (78/01)
Private CO Line = private CO line (P) and g roup number.
(P/xxx)
Alarm Type Alarm level: MAJOR, MINOR, or WARNING
Service State Service state of the station and trunk p orts:
RDY = ready for service
OUT = out of service
IN = in service
[Blank] = No assoc iated service state