DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1242UDS1-BD (UDS1 Interface Circuit Pack)
3
The Far CSU Loopback Test has the TN464F UDS1 Interface circuit pack transmit
a loopback acti vation code to the remote CSU, waits up to 15 second s for return
of the code to verify the loop back has been estab lished, transmits a framed
3-in-24 test pattern, beg ins counting bit errors in the rec eived test pattern, and
returns a PASS result. If the loopback is not established within the 15 seconds,
the test fails.
The status of the Far CSU Loopback test will be available in the hardware error
log via error type 3901. Several distinc t aux values will be used to give the user
information of the status of the test.
The
list measurements ds1 summary
command will disp lay the length of time the
test has been running (
Test Duration
field) and number of b it errors detected
(
Loopback/Span Test Bit-Error Count
field). If the test pattern is b eing passed
through the loopbac k cleanly, the number of bit errors should be very low. The
command will also disp lay the type of Loopb ack/Span test executing (
Tes t
field),
the type of pattern gener ated for the type of Loopb ack/Span test (
Patter n
field),
and whether the pattern (
i.e.
3-in-24 Pattern
) is synchronized (
Synchronized
field).
To terminate the test, enter the
test ds1-loop UUCSS end-loopback/span-t est
command or the release board c ommand. Using the release board c ommand
will restore all trunks or ports on the TN464F UDS1 Interface circuit p ack to the
in-service state.
Table 3-532. TEST #1213 Far CSU Loopback Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the
test ds1-loop UUCSS far-csu-loopback-test-begin
command at
1-minute intervals a maximum of 5 times.
1005 ABORT Far CSU Loopback Test cannot be executed in the current configuration. To
run this, the TN464F or later suffix UDS1 must be administered for 24-channel
operation. The "Bit Rate" field on the DS1 circuit pack administration form must
be set to "1.544" for 24-channel operation.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been b usied out to
out-of-service.
1. Enter the busyout board UUCSS command to put all trunks or ports of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
Continued on next page