DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-28change system-parameters maintenance
2
CPE Alarm
Activation
Level
Indicates the minimum level (Major, Minor or Warning) to activate
Customer-Provided Equipment (CPE) alarm. If the level is none, the
CPE does not activate for any alarm.
NOTE:
When the switch goes into Emergenc y Transfer, the CPE alarm
activates regardless of the CPE Alarm Activati on Level setting.
Packet Bus
Activated If this field is set to yes, maintenance software a ssumes that a
Packet Control circuit pac k is installed. If pac ket endpoints (for
example, ASAI, and/or BRI) are administered , and maintenance
testing runs on both the Packet Control c ircuit pack and Packet Bus,
set this field to yes after a pac ket control circu it pack is installed. If a
Packet Control circuit pac k is not installed in the system, a major
alarm is raised against the PKT-CTRL MO.
Change this field to no if no pa cket endpoints are ad ministered, to
ensure that no packet endp oints can be ad ministered if the packet
bus deactivated.
If a Packet Control circuit p ack is not installed, then this field should
be set to no (the only excepti on is system translations that do not
have all required hardware ).
Customer Access
to INADS Port To prevent customer login ID ac cess to system administration and
maintenance interface contr ol, set this field to no. Lucent
Technologies services has sole ac cess to this field.
Repeat Dial
Interval (MMS) Number of minutes that the system must wait before atte mpting
another call origination to an OSS. Lack of a far-end
acknowledgment trig gers the timer.
Scheduled Maintenance
Start Time Hour and minute (24-hour notation) when daily sc heduled maintenanc e
starts
Stop Time The hour and minute when scheduled daily maintenance c eases. If any
daily maintenance ope rations are not completed by this time, the
system notes its stopped sequence location and includes those
operations during the next s cheduled d aily maintenance.
Daily
Maintenance This display-only field lists the stand ard test series run by mai ntenance
software during daily main tenance.
Save
Translation Indicates days that transl ation data in memory automatically saves to
the Mass Storage System disk and/or tap e devices during scheduled
maintenance. The operation saves to disk, then c ompletes a backup to
tape. Translation data saves to both SPEs, if systems have duplic ated
SPEs. (d aily, day s of th e week , or n o - pr event s aut omati c sav es)