DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1091TIE-DS1 (DS1 Tie Trunk)
3
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-484. DS1 Tie Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short T est Sequence first. If all tests pass, run the Lon g T es t S equence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test trunk <grp >/<mbr> sh
r 1>
1 (a) 57476
57477
57485
57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk <grp>/<mb r>
257 (e) 57473
57474
513(f) 57392 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ2
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
769(g) 57393 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ2
1025 DS1 Tie Trunk
Seizure (Test #136) MAJ/MIN/
WRN3
3. Minor alarms on this MO may be d owngraded to Warning alarms b a sed on the values used in the set
options command. If the MINOR alarm is not downgraded by the set options values , the MINOR alarm
is upgraded to a MAJOR alarm if 75 percent of the trunks in this trunk group are alarmed.
OFF test trunk <g rp>/<mbr> r
2
1281 Conferenc e Circ uit
(Test #7) MAJ/MIN/
WRN3ON test trunk <grp>/<mbr> l r
4
1537 NPE Crosstalk Test
(#6) MAJ/MIN/
WRN3ON test trunk <grp>/<mbr> l r
3
1793 (h) test board PCSS long
2305(i) 50944 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ3OFF
Continued on next page