DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-684HYB-LINE (Hybrid Line)
3
HYB-LINE (Hybrid Line)
Hybrid Line is the user-friend ly name for Hybrid Line, whic h was previously used
to denote the Multifunction Analog Telephone. The Hybrid Line set is also known
as an SCS (Small Communications System).
The TN762B Hybrid Line circuit p ack supports eig ht of these multifunction
analog telephone sets, as shown in the fol lowing figure. The Hybrid Line sets us e
three pairs of wires: an analog voic e pair, a transmit/receive pai r, and a power
pair.
Figure 3-20. Hybrid Station Interactions
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for
example, A, B, or C); SS is the address of the slot in the carrier where the circuit pack
is located (for example, 01, 02, ..., etc.); and pp is the 2-dig it port number (for
example, 01).
Full Name of MO
HYB-LINE Minor test port PCSSpp l Hybrid Line
HYB-LINE Warning test port PCSSpp l Hybrid Line
PBX
PORT (1)
VOICE
TERMINAL
HYBRID LINE
(8)
PORT
VOICE
TERMINAL
HYBRID
CIRCUIT
PACK
LINE