DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-647ETH-PT (Control LAN Ethernet)
3
Aux Data indicates the internal ap plication number.
g. Error Type 2305-2816: System software detected a session is d own. Aux
Data indicates the session numb er. These are log only errors. Error types
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for
session numbers 257-512.
h. Error Type 3329: TCP/IP Ping Test failed.
1. Test port (test port UUCSSpp short).
2. Refer to TCP/IP Ping Test (#1281) repair proced ures.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors in the order they ap pear in the table below.
Error Type Application
1793 Unused
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway
1798-1920 Reserved for
future
Table 3-267. Sys tem Technician-Demanded Tests: ETH-PT
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-destructive
Ethernet Local Loop-Around Test (#1278) X D
TCP/IP Ping Test (#1281) X X ND
Session Status Test (#1286) X X ND
Link Integrity Inquiry Test (#1282) X X ND