Maintenance Objects
3-490DIG-IP-STN (Digital IP Station)
3
DIG-IP-STN (Digital IP Station)
This maintenance object co vers implementation of the maintenance for
Lucent-provided IP Softphone or the Centre-Vu Remote IP Agent. The
Lucent-provided endpoint consists of a service provider, an ap plication layer
called the Telephony Manager, and a reg istration applic ation. The service
provider terminates DCP signaling carried over TCP. The Telephony Manager
provides the GUI emulating the DC P set. The registration application hand les
H323.RAS and is used to register and authentic ate the endpoint with DEFINITY.
This group of modules is calle d Vphone. Note that the Vphone does not inc lude
any type of audio path of b earer channel. The Vphone provides a DCP c ontrol
plane for an alternate bearer c hannel. Tha alternate bearer channel is provid ed
by either a native H.323 station or a POTS line or trunk. The Vphone is used only
in a dual-connect arrang ement.
The Vphone supports some level of existing DCP maintenance in the form of
audits and upd ates.
This station type is not attached to a p ort board. Insertion of the s tation is not
driven by board insertion, rather it is driven b y successful registration of t he
endpoint. It is maintained via a set of explicit TCP/IP ping requests and errors
reported by the User Mang er software, which terminates the H.323 sig naling
portion of each endp oint. The MO follows standard mtce me thodology and
supports test, busy out, release and status command s.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run Full Name of MO
DIG-IP-STN WARNING test station
extension
Digital IP Station
Table 3-205. DIG-IP-STN Digital IP Station Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0 0 Any Any test station
extension
1 (a) Registration Status Inquiry
(#1372) WARNING OFF
257 (b) Signaling Path PING Test
(#1373) WARNING OFF
(c) Digital Terminal Lamp
Update (#16) WARNING OFF
(d) Digital Terminal Audit
Update (#17) WA RNING OFF
Continued on next page