DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-144ATM-EI (Expansion Interface Circuit Pack)
3
ATM-EI-related commands
The following commands may b e helpful in resolving ATM-EI problems:
Replacing an ATM-EI circuit pack
Standard Reliability
1. Enter busyout atm-pnc # (this will affect service) at th e DEFINI TY SAT.
2. Replace the ATM-PNC circuit pack and re-c onnect the fiber.
3. Enter release atm-pnc.
4. Wait 2.5 minutes for board insertion.
5. Enter list sys-link to verify that the links are up.
6. Enter test board UUCSS and verify that all tests pass.
High Reliability
There are 2 ATM-EI circuit packs in the PPN, 1 in the EPN.
1. Enter busyout atm pnc # at the DEFI NITY SAT.
NOTE:
If the ATM-EI is in an EPN, this will affect service.
2. Replace the circuit p ack.
3. Enter release atm pnc.
4. Wait 2.5 minutes for board insertion.
5. Enter list sys-link to verify that the links are up.
6. Enter test board UUCSS and verify that all tests pass.
add atm pnc list measurements atm
busyout/release atm pnc remove atm pnc
busyout/release board reset board
change system-parameters
customer-options (atm pnc ) status atm-pnc
change atm pnc
(pnc dupl ication) status cabinet
display atm pnc status port-network
list atm oam-statistics test board
list atm pnc