Maintenance Objects
3-97ANN-BD (Announcement Circuit Pack)
3
!WARNING:
All alarms are upgraded to MAJOR when the BASE Tone Generator is set to 12 (France).
Notes:
a. Error Type 1This error indicates the circuit pac k totally stopped
functioning or it was physic ally removed from the system.
NOTE:
The alarm is logged abo ut 11 minutes after the circuit pack has b een
removed and/or SAKI Test (#53) fails.
If the circuit pac k is not in the system, insert a circuit pa ck (in the same
slot as the error indicates) to resolve this error. Or, if the c ircuit pack is in
the system and the red LED is on, follow the instruc tions for "Red (alarm)"
in the "Control and Port Circuit Pack Status LEDs" section in Chapter 7,
"LED Interpretation".
NOTE:
The alarm is logged abo ut 11 minutes after the circuit pack has b een
removed and/or SAKI Test (#53) fails.
!WARNING:
Reseating and/or replacing the circuit pac k results in loss of integrated announcements (TN750/B only). See ‘‘General Notes’’ near the beginning of th is Maintenance procedure.
17699
(m) In-line Error
3840 (n) Any None
3999 (o) Any None
1. Run the Short T est Sequence first. If all tests pass, run the Lon g T es t S equence. Refer to the appropriate
test description and follow the recommended procedures.
Table 3-36. Announcement Circuit Pack Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm Level (See
WARN IN G
message below)
On/Off
Board Test to Clear Value
Continued on next page