DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-795MEDPRO (Media Processor MAPD Circuit Pack)

3
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 -This error indicates that the circuit pac k has totally stopped functioning or is not fully ad ministered. The alarm is logged about 15 minutes after the circuit pac k has been removed or 11-minutes after the
SAKI Test (#53) fails.
Table 3-341. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test board UUCSS
1(a) 0 Circ uit pack removed or
SAKI Test (#53) MIN/WRN2
2. If ports are assigned to the circuit pac k, then a minor alarm is raised. If no p orts are assig ned to
the circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has b een
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered
on the circuit pack.
ON
18(b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 WARNING OFF add ds1 UUCSS
125(d) None None MIN/WRN3
3. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
ON
257(e) 65535 Control Channel Loop Test
(#52) MINOR ON test board UUCSS l r 2
257(e) Any None
1538 Any Hyper activity MIN/WRN3ON
1793 Any NIC Los Of Signal MIN/WRN3test board UUCSS l r 2
2049(f) Any NT PC Failu re MIN/WRN3reset board UUCSS
2305 Any IP Address Inconsistency test board UUCSS l r 2
2561 Any Ping Error MIN/WRN3test board UUCSS l r 5
3841(g) 4358 Log Only
3999(h) Any None
Continued on next page