DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-428DATA-CHL (Data Channel)
3
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates that the c ircuit pack has b een removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
System Technician-Demanded Tests: Descriptions
and Error Codes
There are two system technician test command s that include the Data Channels
(DATA-CHLs). The test data-module <ext> [short | long] command tests the
single DATA-CHL that has the extension specified by < ext>. The test
network-control [short | long] command tests each adm inistered DATA-CHL
that resides on the Processor circuit p ack in the specifi ed carrier.
Always investigate tests in the order p resented in the following tabl es when
inspecting errors in the s ystem. By clearing error cod es associated with the
Data Channel Reset Test,
for example, you may also clear errors generated from other
tests in the testing sequenc e.
Table 3-183. Data Channel Erro r Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01(a)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test data -module <ext> sh r 1
1 Any Local Loop Back Test
(#111) MINOR ON test data-module < ext> sh r 3
18 0 busyout data-mod ule
<ext> WARNING OFF release data-module <ext>
130 None WARNING ON test data-module < ext> sh
257 Any Remote Maintenance
Loop Around Test
(#109)
MINOR ON test data-module < ext> sh r 5
513 Any Crosstalk Test (#110) MINOR ON test data-module < ext> sh r 3
769 Any Dual Port RAM Test
(#108) MINOR ON test data-module < ext> l r 3