DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-136ATM-BCH (ATM B-Channel Trunk)
3
1020 ABORT TN230x circuit-pack problem
1. See the ‘‘ATM-INTF (TN2305/6)’’ maintenance object.
1024 ABORT Maintenance/Test Digital Port in use
1. Wait until yellow and green LEDs on the Maintenance/Test circuit pack
are OFF.
2. Rerun the test.
3. If the problem persists, see the M/T-DIG (Maintenance/Test Digital Port)
maintenance object.
1113 ABORT Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check Test).
1116 ABORT Switch could not change the service state
1. See if calls are active. Run status trunk
grp#/mbr#
.
2. If a call is active. proceed as for Error Code 1119.
3. If not, check the Error and Alarm Logs and refer to the ATM-TRK (Circuit
Emulation Service Circuit Pack) maintenance object.
1117 ABORT ISDN service message outstanding
1. Wait 2 minutes. Then try again.
1118 ABORT Far-end not administered
1. Check the administrat ion of the far-end of the ATM trunk. Run status
trunk
grp#/mbr#
.
2. Try the test again.
1119 ABORT Test call aborted, normal call attempted
1. Wait for the call to terminate normally or drop it by running busyout
trunk
grp#/mbr#
.
2. When the trunk is idle, retry the test.
1120 ABORT Trunk OUT-OF-SERVICE/FAR-END
1. Try to change the service state via Test #256 (Service State Audit Test).
2. Try the test again.
1122 ABORT No test-line number for the far-end switch
1. Check the Trunk Group Administration form.
1123 ABORT No Feature Access Code administration for this Facility Test
1. Check the Dial Plan and Feature Administration forms.
Table 3-56. TEST #258 ISDN Test Call — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page