DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-382CO-DS1 (DS1 CO Trunk)
3
Port Audit and Update Test (#36)
This test sends port level translation d ata from switch processor to the DS1
Interface circuit p ack to assure that the trunk’s translation is c orrect. Translation
updates includ e the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circ uit pack
and in the switch software.
PASS The port can correctly conference multiple connec tions. User-reported
troubles on this port should be investigated by using other port tests and
by examining station, t runk, or external wiring.
0NO
BOARD The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, an insane board is inserted, or the b oard is
hyperactive (see note below).
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
this is not the case, dispatch to check to ensure that there is a valid board
inserted.
NOTE:
Hyperactivity causes some special problems with the sequence
suggested above.If the ports are translated after issuing the list
config command but the Vintage field reports that there is no
board (when there really is a b oard), then the busyout boa rd and
the release busy board commands will not work (even though the
reset board command will work). The software puts the hyperactive
board back in service after the hyperactivity clears.
Table 3-168. TEST #7 Conference Circuit TestContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page