DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-754ISDN-TRK (DS1 ISDN Trunk)
3
restricted (ZCS) the default durat ion of the test call is 9.4 second s. Once the test
call completes, the b it error rate is retrieved from the Maintenance/Test Digital
Port. A bit error rate greater than zero is reported as a failure to the Manager I
terminal (MGRI). A failure indicates the need to run further diagnostic s, such as
the test isdn-testcall command.
If no Maintenance/Test circuit pack exists, the ou tgoing ISDN-PRI test call is
established over a high sp eed data chann el on the Network Control (NETCON)
circuit pack (DATA-BD).
Asynchronous Commands
You can start, query, and stop an outgoing test call by using the fol lowing
maintenance commands:
test isdn-testcall trunk-group-no/member-no [ minutes ]
This command enables you to start an outg oing ISDN-PRI test call for a
maximum of two hours (120 minutes).
status isdn-testcall trunk-group-no/member-no
This comman d displays the pr ogress of the o utgoin g t est cal l by repor ting
the bit and bloc k error rates of the tested B-channel sp ecified by the "trunk
group no/member no" identifier.
clear isdn-testcall trunk-group-no/member-no
This command enables you to stop an outgoing test call al ready in
progress. The trunk-group-no/member-no identifier spec ifies the
B-channel used to stop the test call. The measurements are not cleared
until the next test call begi ns.
NOTE:
Only one trunk can be tested in a given port network, until the test call is
canceled or com p letes.
Table 3-318. TEST #258 ISDN TEST Call
Error
Code
Test
Result Description/ Recommendation
4 ABORT There is a problem with the Processor Interface Link.
1. Refer to PKT-INT (Packet Interface).
8 ABORT There is a problem with the DS1 interface circuit pack.
1. Refer to DS1-BD (DS1 Interface Circuit Pack).
Continued on next page