DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-630E-DIG-STA (Emulated Digital Line)
3
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequenc e
and only one test path in the test seq uence. Once the test seq uence is started,
all tests in the test sequence are exec uted.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pac k
and the hardware connec ted to those ports for lines ad ministered as a digital
station. These include stations with an emulated digital voice termi nal and
stations with an emulated dig ital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand -alone mode are not
supported b y the TN800 circuit pac k. Circuit pack maintenanc e is covered by
E-DIG- BD.

Hardware Error Log Entries and

Test to Clear Values

MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for
example, A, B, or C); and SS is the ad dress of the slot in the carr ier where the circuit
pack is located (for example, 01, 02, ...).
Full Name of MO
E-DIG-STA MINOR test port PCSSpp l Emulated Digital St.
E-DIG-STA WARNING test port PCSSpp sh Emulated Digital St.
Table 3-259. Digital Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
18 (a) 0 busyout p ort PCSSp p WNG OFF re l por t PCSSpp
130 (b) None WNG ON test port PCSSpp sh
1793 (c) Voice and Control Local
Loop Test (#13) MIN/
WNG2ON test port PCSSpp l r 3
2049 (d) NPE Crosstalk Test (#9) MIN/
WNG2ON test port PCSSpp l r 3
2305 (e) 32770 None
Continued on next page