DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-474DID-TRK (DID Trunk)
3
Additional in-line testing is performed while a c all is in progress. Thus, in-line
errors may occur during op eration. See Error Log table for a descripti on of these
errors. These errors may be reproduced by using the trunk (that is, p lacing a call)
and checking their occurrence in the Hard ware Error Log.
Problems detected d uring signaling may b e caused by faults off-b oard (in the
CO switch or connections) for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must b e idle. If an
incoming call seizes the p ort which is being tested by maintenanc e, the test is
aborted, and the inc oming call proc eeds.
For transmission and signaling sta ndard specific ation, refer to Digital PBX
Standards document RS4648.
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-200. DID Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
010 Any Any Any t est po rt PCSSpp sh r 1
1 (a) Any None WRN OFF
1 (b) 57476 None WRN OFF
1 (c) 57477 None WRN OFF
1 (d) 57483 None WRN OFF
15 (e) Any Port Audit Update
(#36)
18 0 busyout trunk
<grp/mbr> WRN OFF release trunk <g rp/mbr>
130 (f) None WRN ON test trunk <grp>/<mbr>
257 (g) 57472 None WRN OFF
257 (h) 57473 None WRN OFF
257 (i) 57474 None WRN OFF
257 (j) 57475 None WRN OFF
513 (k) 57392 None MAJ/MIN/
WRN2OFF
510 (l) 57393 None
769 Any Port Diagnostic
(#35) MAJ/MIN/
WRN2ON test p ort PCSSp p r 3
Continued on next page