DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-352CLAN-BD (Control LAN Circuit Pack)
3
The Error Types correspond to the de scriptions:
1. Refer to Congestion Query Test (# 600) for Abort and Fail 3601s.
o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test
(#601) failed. This failure may be due to:
This circuit pack
The packet bus
The packet interface c ircuit pack.
p. Error Type 3330: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace c ircuit pack.
q. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold numb er of errors. One or more of the following
symptoms may be present:
Circuit pack por t tests return NO BOARD.
List configuration com mand shows circuit p ack and ports are
installed properly
2817 All buffers exhausted.
2819 Utilized buffers exceed threshold.
If: Then:
Active buffers exceed threshold, CLAN enters congested state.
If: Then:
RSCL disconnects at link level Link fails
Link cannot be reconnected quickly Switch raises MINOR alarm
If the switch detects: Then it:
1 error, Resets circuit pack.
2 errors in 15 minutes, Raises MINOR alarm.