DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-864OPS-LINE (DS1 OPS Line)
3
PASS The station hook states in both switch software and DS1 Interface circuit pack
are consistent.
0
2012 NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect bo ard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Table 3-374. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page