DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-420DATA-BD (Data Channel Processor Circuit Pack)
3
Notes:
a. This error indicates the DATA-BD portion of the Processor circuit pack
stopped func tioning. Since the Processor circ uit pack cannot b e reset via
the reset board PCSS command, the Data Chan nel Reset Test (#107) in
the Long Test Sequence for the DATA-CHLs must be used to reset it as
follows:
1. Issue the list data command to determine if one, or more, Data
Channels (DATA-CHLs) is administered.
NOTE:
A Data Channel (DATA-CHL) is identified by a "type" value of
"netcon."
2. If a Data Channel (DATA-CHL) is not administered, use the add
data-module [<ext> | next] command to administer a DATA-CHL.
3. From the form resulting from the list data command, c hoose a Data
Channel (DATA-CHL).
4. Issue the test data-module <ext> long command using the
extension for the DATA-CHL chosen in Step 3.
!WARNING:
Issuing this command drops all data c hannel extensions. See DATA-CHL (Data Channel) Maintenance documentation first.
769 (e) 4358 None
1025 (f) 4363 NPE Audit Test (#50) test network-control [a | b]
sh
1538 (g) Data Channel Reset
Test (#107) MINOR ON test data-module <ext> l
3840 (h) Any None
3999(i) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
Table 3-180. Data Channel Processor Circuit Pack Error Log Entries — Continued
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page