DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-128ATM-BCH (ATM B-Channel Trunk)
3
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call
state. Possible causes:
Received a DISConnect or RELease COMplete message with
cause value 52 (outgoing calls barred)
Received a DISConnect or RELease COMplete message with
cause value 54 (incoming calls barred)
Outgoing call reneg otiated by the far end to an other B-channel in
the absence of SETUP message glare
Near end attempted a c all on a B-channel that the far end ha s
marked OOS
When running the Short Test Sequence, pay close attention to the results
of the Call State Audit Test (#257).
Table 3-51. ATM-BCH Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSppp
1(a) Any None test port UUCSSppp
18 0 busyout trunk
grp/mbr
release trunk grp/mbr
129 (b) None WNG OFF test port UUCSSppp
130 (c) test port UUCSSppp
257(d) Any Service State Audit (Test
#256) test port UUCSSppp
513(e) Any None WNG OFF test port UUCSSppp
769(f) Any Service State Audit (Test
#256) test port UUCSSppp
1793(g) Any None test port UUCSSppp
3073(h) Any Service State Audit (#256) test port UUCSSppp
3585(i) Any No ne none
3841(j) Any None WNG OFF none
Continued on next page