3-627DTMR-PT [Dual Tone Multifrequency Port (TTR)]
3
Table 3-258. TEST #43 Tone Detector Audit/Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT The system was not able to allocate all the resources needed for this test.
1. Wait one minute and try again.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL Hardware audit failed.
1. Run the Short Test Sequence: test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but
system capacity is reduced. In order to restore the system
performance to nor mal, replace the Tone Detector circuit pack
containing the defective DTMR port.
PASS The DTMR port has been successfully refreshed with its translation.
Continued on next page