DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1189UDS1-BD (UDS1 Interface Circuit Pack)
3
Internal Looparound Test (#135)
This test is destructive.
The Internal Looparound Test is run by looping the transmitt ed DS1 bit stream
back into the UDS1’s board receiver. The loop occurs just before the DS1 facility
interface. The test is highly destru ctive and can only b e initiated by a system
technician-demand ed reset board UUCSS command.
All trunks or ports on the UDS1 Interface c ircuit pack must b e busied out via the
system technician busyout board command before running the Internal
Looparound Test. When the Internal Looparound Test is initiated, maintenance
software sends appropriate mess ages to the UDS1 Interface circuit pac k to start
the test. The test uses the Tone Generator and Tone Detector to exercise a bit
pattern consistency tes t for all ports. If the transmitted and received bit p atterns
on a trunk or port are different, the test fails.
When the test is complete, the maintenance software sends a stop loop around
message to the UDS1 Interface circ uit pack to put the c ircuit pack b ack into the
normal operation mode. All trunks or ports of the UDS1 Interface circ uit pack are
restored to the in-service state after the release bo ard command is entered.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 3-517. TEST #53 SAKI Sanity Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page