DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-185ATM-EI (Expansion Interface Circuit Pack)
3
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present, or some tone detectors may be out of service.
1. Resolve any TTR-LEV errors.
Even if there are no TTR-LEV errors, there may not be a tone
detector available on the network that contains the circuit
pack being tested. Verify that there is at least one tone
detector on the network. If not, this test always aborts for this
ATM-EI circuit pack and does not harm the system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 3 times.
1962 ABORT All DSPs are busy (an unlikely event).
1. Retry the command at 1-minute intervals a maximum of 3
times.
2000 ABORT Response to the test was not received within the allowable time
period for some of the DSPs.
1. If the board is in standby, reset the board and run the test
again.
2. Look into the Error Log for Error Type 1218 (bad DSP). If
Error Type 1218 is not logged against this board, run the
DSP test again and see if the error persists.
2100 ABORT Could not allocate the necessary system resources to run this
test.
2302 ABORT Inconsistent uplink message from the ATM-EI board (an unlikely
event).
1. Retry the command at 1-minute intervals a maximum of 3
times.
2500 ABORT Internal system error
2752 ABORT The circuit pack in this location is not a TN230X.
Table 3-77. ATM Board DSP Test (#1293) — Continued
Error Code
Test
Result Description/ Recommendation
Continued on next page