DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1298XXX-BD (Common Port Circuit Pack)
3
PASS This circuit pack is a TN746 or TN769 Analog Line circuit pack and the
neon current is detected. This test also returns PASS for circuit packs that
are not TN746 or TN769 circuit packs, but the test is not run on the circuit
pack and the results of this test can be ignored.
any NO
BOARD This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there is
some inconsistency between the physical configuration and the data kept
in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 3-556. TEST #220 Neon Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page