DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-492DIG-IP-STN (Digital IP Station)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the table below whe n
inspecting errors in the sy stem. By clearing error cod es associated with the
Signaling Path PING Test, for example, you may also clear errors generated from
other tests in the testing sequenc e.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Registration Status Inquiry (#1372) X X ND
Signaling Path PING Test (#1373) X X ND
Digital Terminal Lamp Update Test (#16) X X ND
Digital Terminal Audits Test (#17) X ND