DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1146TONE-PT (Tone Generator)
3
Table 3-504. TEST #90 Tone Generator Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
None ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1001 ABORT The system was not able to put the tone generation facility in the
appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM-BUS via the test tdm port-network PN#
command. Refer to TDM-BUS section for details.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Tone Generator could be defective.
1. Test the Tone-Clock circuit pack again via the test tone-clock PC
command
2. If the test fails again, look at the Hardware Error Log for Tone Detector
circuit pac k errors.
3. If there are Tone Detector circuit pack errors, refer to Tone Detector
Maintenance documentation (DTMR-PT, GPTD-PT, CLAS-PT, ETR-PT)
to resolve these errors first.
4. If there are no Tone Detector circuit pac k errors, then the Tone-Clock
circuit pack should be replac ed. See ‘‘How to Replace a Tone-Clock
Circuit Pack’’ in the TONE-BD section.
PASS The tone generation facility is able to put tones out.