DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-260BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
3
BRI-BD/LGATE-BD (ISDN-BRI Line
Circuit Pack)
NOTE:
Some of the information in this section is reserved for futu re use.
ISDN-BRI Line is a packet port circ uit pack that provid es access to ISDN-BRI
endpoints. The ISDN-BRI Line circuit pac k supports 12 po rts, each of which
provides access to ISDN stations. Voice and c ircuit-switched d ata from the ISDN
stations are carried on the Time Division Multip lex (TDM) Bus.
LEDS
The ISDN-BRI Line circuit pack performs ex tensive initialization tests and lights
both the red and g reen LEDS during the initialization testing. See ‘‘LED
Interpretation’’ in Chapter 1, ‘‘Maintenance for c si systems’’, for more details on
circuit pack sta tus LEDs.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run1
1. Where P is the port network number (1 for PPN); C is the carrier designation (A, B, or
C); and SS is the address of the slot in the carrier where the circuit pack is located
(01, 02, ..., etc.).
Full Name of MO
BRI-BD MAJOR test board PCSS l ISDN-BRI Line Circuit Pack
BRI-BD MINOR test board PCSS l ISDN-BRI Line Circuit Pack
BRI-BD WARNING test board PCSS sh ISDN-BRI Line Circuit Pack
LGATE-BD MAJOR test board PCSS l DEFINITY Lan Gateway
LGATE-BD MINOR test board PCSS l DEFINITY Lan Gateway
LGATE-BD WARNING test board PCSS sh DEFINITY Lan Gateway