DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-811MEDPROPT (TN802 MED PRO DSP PORT)
3
0NO
BOARD No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues, if
applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the NCE chip on board may be bad.
Replace the board and retest.
Table 3-352. TDM NIC Looparound Test (#1380) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page