Maintenance Objects
3-1116TIE-TRK (Tie Trunk)
3
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out-of-servi ce.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT (Non-TN497 circuit packs only.) The port was seized by a valid call d uring
the test. The test has been aborted. Use the display trunk xx command to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, the port is unavailable for certain
tests. You must wait until the port is idle before retesting.
1018 ABORT The test has been disabled via administration.
Verify that the ’Maintenance Test’ field on the ’Trunk Group’ form is set to
’n’. To enable the test, issue the change trunk-group x command (x
equals the number of the trunk group to be tested). Then, change the entry
in the Maintenance Test field on the form to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-492. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page