Tie Trunk EPF Test (#74)

This test consists of an E lead and M lead tes t. The E lead test checks for the

proper activation and deactivation of the p ort’s E lead. The M lead test chec ks

the M lead EPF current flow. The processor sends an M lead test req uest to the

circuit pack and receives the results. The returned results are measured to see if

a port or external tie trunk line fails.

Table 3-495. TEST #74 Tie Trunk EPF Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run the test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The trunk may
be busy with a valid call. Use the display trunk xx to determine trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), then
check the Error Log for Error Type 1025 (see Error Log table for
description of this error and required actions). The port may be locked
up. The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display trunk xx to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is in use,
the port is unavailable for certain tests. You must wait until the port is idle
before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT This test is not valid for this trunk translation. Must be a Type-1 standard
trunk for this test to run.
1. Check trunk configuration. If it is not a Type-1 standard trunk, this abort
message should be ignored.
Continued on next page