DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-374CO-DS1 (DS1 CO Trunk)
3
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-166. DS1 CO Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short T est Sequence first. If all tests pass, run the Lon g T es t S equence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test trunk <grp >/<mbr>
1 (a) 57408
1 (a) 57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk <grp>/<mb r>
257 (e) 57392 DS1 CO Dial Tone
Seizure Test (#314) MIN/MAJ2
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
OFF
513 (f) 57393 DS1 CO Dial Tone
Seizure Test (#314) MIN/MAJ2OFF
769 (g) 57484
1025 DS1CO Dial Tone
Seizure Test (#314) WARNING OFF test trunk <grp> /<mbr>
1281 Conference Circ uit
Test (#7 ) MAJ/MIN/
WRN3
3. Minor alarms on this maintenance object (MO) may be downgraded to Warning alarms based on the
values used in the set options command. If the Minor alarm is not downgraded by the set options
values, the Minor alarm is upgraded to a Major alarm if 75 percent of the trunks in this group are
alarmed.
ON test trunk <grp>/<mbr> r
4
1537 NPE Crosstalk Test
(#6) MAJ/MIN/
WRN3ON test trunk <grp>/<mbr> r
3
1793 (h) ON test board PCSS l
2562(i)) 16665
2817(j) 52992
3840 (k) Port Audit and
Update Test (#36)
Continued on next page