DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-10How to use the Maintenance book
1
17. Perform both steps in the Descrip tion/Recommendation column.
18. Test the port (test port 01C1008 long and press Ente r.) again after all of
the recommendations are exhausted.
19. If all tests pass, wait approximate ly 3-5 minutes for the Alarm and Error
logs to clear.
20. Type display alarms and p ress Enter twice.
21. Check that the DID-TRK alarm does not app ear in the log.
Field descriptions
Table 1-3. TEST #35 Port Diagnostic Test
Error
Code
Test
Result Description/Recommendation
61472 FAIL Battery feed test failed. A problem with the incoming CO line was
detected.
1. Check the incoming CO line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO line checks out Ok, the failure must be on the DID port.
Replace the circ uit pack.
Continued on next page
Error type Enter error type, or blank
Error List active-alarms, errors, or cleared -errors
Interval h(our), d(ay), w(eek), m(onth), a(ll)
From:/To: Specify time interval by date a nd time
Cabinet Enter cabinet number (1 - 44)
Port Network Enter port network number (1 - 44)
Board Number Enter 5-character board number in UUCSS format:
cabinet (1-44), carrier (A-E), slot (0-20)
Port Enter 7-character port add ress in UUCSSss format:
cabinet (1-44), carrier (A-E), slot (0-20), c ircuit
(01-31)
Category Enter category name (choose 1 from the list below:
adm-conn announce bri/asai cdr data-mod
detector dup-spe environ exp-intf ext-dev
generatr inads-link infc maint mass-st