DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-916PMS-LINK (Property Management System Link)

3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. The PMS Link has been busied out for system technic ian-demanded maintenance via the busyout pms-link command. The link is tor n down. Enter the release pms-link command to restore the link.
Table 3-393. PMS-LINK Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short T est Sequence first. If all tests pass, run the Lon g T es t S equence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-link
257 (b) 0-6,
99,
255
Link Retry Test
(#215) MINOR/
WARNING 2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF test pms-link l
513 (c) 0-6,255 None test pms-link
769 (d) 0-6,255 None
1025 (e) 4x3
3. Is any integer.
None
1281 (f) 1x3None
1537 (g) Nx3None
1793 (h) 0-6,255 None test pms-link
2049 (i) 0-6,255 None
2305 (j) 5x3None release pms-link or test
pms-link
2561 (k) 0-6,255 None test pms-link
2817 (l) 10x3
20x3
30x3
None
3073 (m) 7x3None
3841 (n) 2x3None
Continued on next page