Table 3-491. TEST #6 NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The trunk may
be busy w ith a va lid call. Use the displ ay trun k xx command t o determ ine
the trunk group/member number of the port. Use the status trunk
command to determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for certain tests. You
must wait until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no connected
ports), check the Error Log for Error Type 1025 (see Error Log table for
description of this error and required actions). The port may be locked
up.
2. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT System resources required to run this test are not available. This could be
due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to TDM-BUS Maintenance to diagnose any
active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-servi ce.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1004 ABORT (Non-TN497 circuit packs only) The port was seized by a valid call during
the test. The test has been aborted. Use the display trunk xx command to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, the port is unavailable for certain
tests. You must wait until the port is idle before retesting.